Guides / Calculators

Range Hood CFM Calculator

How much CFM do you need? Choose your range details for an instant planning estimate.

Your cooking setup

Cooktop type
Hood location

Total surface-burner output. Do not include the oven.

Add a size to check it against the airflow estimate.

Recommended planning range

600–800 CFM

Based on your BTU band. Confirm the exact appliance requirement; the lower end will not suit every model.

Explore ventilation options

Planning estimate only. Confirm final airflow with the appliance and hood instructions, ductwork and local requirements. Built-in grills, griddles and specialty equipment need separate guidance.

Hood width example

42″ hoodover a 36″ range

Adds 3 inches per side where specifications allow. Depth and mounting height also matter. Hood coverage guide

Plan for makeup air

This estimate extends above 400 CFM. Check the selected equipment’s maximum exhaust capacity and local requirements.

Makeup-air guidance

The sizing guide

Understand your range hood CFM.

Airflow tables, duct guidance and manufacturer references for planning your ventilation.

The short answer

How much CFM do I need for my range hood?

The right airflow depends on the cooking equipment, the hood’s ability to capture what rises from it, and the resistance in the route outdoors.

CFM means cubic feet per minute: a volume of air moved in one minute. A fan’s published rating is useful, but the complete installation determines how much air is delivered. A hood with poor coverage or a restrictive duct can disappoint even when its advertised CFM looks generous. Conversely, choosing the largest available blower without considering the room, noise and makeup air can create a different set of problems.[2]

Use the calculator to establish an early planning value. It compares a width-based screen with a gas-output screen when relevant, then provides an optional duct check and makeup-air guidance. It does not silently convert a small duct into permission to undersize the fan, or turn a light-cooking preference into a lower appliance requirement.

A useful specification resolves the hood’s proportions and its ventilation components together. Start with the cooking surface, use the applicable manufacturer guidance, then match the canopy, insert, blower, controls and duct route as a system.

Visible, repeatable math

How this CFM calculator works

The selected BTU band sits alongside a general width reference. The displayed range updates as selections change; its applicability depends on the project. The result is labeled a planning estimate because it does not model capture efficiency, fan curves, pressure loss or the local code requirements for a particular home.

Width-based airflow screen

Wall: width in inches ÷ 12 × 100
Island: width in inches ÷ 12 × 150

These rates come from HVI’s general kitchen range hood guidance. The island rate reflects a different placement condition. HVI specifically directs professional-style cooktops to the cooktop manufacturer’s advice; a general width table is not a substitute for it.[1]

Gas-output planning screen

Applicable gas output in BTU/h ÷ 100 = CFM screen

The 1-CFM-per-100-BTU guideline is supported in manufacturer literature for stated applications. Thermador’s planning guide describes it for certain installations using non-approved hoods, and includes separate provisions for grills and griddles. The guide does not explicitly resolve oven inclusion for every Professional range. The calculator uses surface-burner output as a clearly identified preliminary screen; the equipment instructions must resolve the required output basis and any additional provisions.[3]

For an ordinary gas configuration with both inputs available, this tool displays the greater of the width screen and gas-output screen. This is a transparent planning comparison, not a new industry standard. It is not appropriate to add those two values together: that would combine two screens without evidence for the resulting total.

For electric and induction equipment, the general width screen is used where applicable. Do not convert electrical input to BTU simply to force an appliance through the gas rule. Professional-style gas, electric and induction equipment requires its own ventilation guidance; this simplified tool does not identify or verify an appliance model.

What the result does not assume

The tool does not apply an automatic “chef” multiplier, a fixed CFM addition per elbow, or a maximum capacity assigned solely to a duct diameter. A BTU band produces an approximate interval by applying the stated calculation to both band boundaries, with the width reference applied to each endpoint. The upper display is rounded to the next whole CFM. This interval reflects uncertainty about the input; it is not a manufacturer-approved operating range. The open-ended 120,000+ band displays 1,200+ CFM under the stated method; it does not imply an upper limit or confirm that a 1,200-CFM blower is sufficient. Electric and induction selections use the applicable width starting point without inventing a range.

How do CFM, CFS and air velocity relate?

CFM is volume per minute; air velocity is distance per minute. When average duct velocity is measured in feet per minute, CFM = velocity × duct area in square feet. Divide square inches by 144 to obtain square feet. Multiply cubic feet per second (CFS) by 60 to obtain CFM. A single point velocity reading does not necessarily represent the average across a duct.

For whole-room air-change arithmetic, CFM = room volume in cubic feet × air changes per hour ÷ 60. That calculation describes room air exchange; it does not establish whether a canopy captures the cooking plume. It is therefore not used to resize the result here.

Range hood CFM by stove width

This quick-reference table shows the general HVI width calculation. It is useful for understanding the relationship between appliance width and placement before equipment-specific requirements are considered.

General width-based estimates, in CFM
Cooking widthWallIsland
24 inches200300
30 inches250375
36 inches300450
42 inches350525
48 inches400600
60 inches500750

Calculated from HVI’s 100/150 CFM per linear foot guidance. These are not universal minimums or professional-range recommendations.[1]

Example: a conventional 36-inch cooking surface against a wall produces a 300-CFM width screen. The same width on an island produces 450 CFM. A gas-output requirement or a model-specific instruction can be higher than either figure.

BTU-to-CFM reference table

The following values show the arithmetic of the gas-output screen. They are examples of the stated method, not a list of universally approved fan sizes.

Illustrative output ÷ 100 calculations
Applicable gas outputCalculationCFM screen
30,000 BTU/h30,000 ÷ 100300
40,000 BTU/h40,000 ÷ 100400
60,000 BTU/h60,000 ÷ 100600
80,000 BTU/h80,000 ÷ 100800
100,000 BTU/h100,000 ÷ 1001,000
120,000 BTU/h120,000 ÷ 1001,200

Use only where the method is applicable. Specialty equipment and model instructions may change the assessment.[3]

How the six BTU bands translate

These are practical input categories, not industry classifications. The values below show the output-only arithmetic before the width reference is considered. Upper limits are rounded for an approximate planning interval.

BTU selector bands and approximate output-based CFM
Cooktop BTU/hOutput ÷ 100
Under 40,000Below about 400 CFM; apply width reference
40,000–59,999About 400–600 CFM
60,000–79,999About 600–800 CFM
80,000–99,999About 800–1,000 CFM
100,000–119,999About 1,000–1,200 CFM
120,000 or more1,200+ CFM; no upper limit inferred

Each displayed endpoint is the greater of the applicable width reference and that endpoint’s output calculation. For example, a 60-inch island cooking surface has a 750-CFM general width reference, so selecting “Under 40,000” gives 750 CFM, not an estimate below the width reference. Specialty and manufacturer-specific restrictions still apply.

A worked 36-inch example

Assume a wall-mounted gas cooking surface with six burners totaling 60,000 BTU/h and no specialty components. The width screen is 36 ÷ 12 × 100 = 300 CFM. The gas-output screen is 60,000 ÷ 100 = 600 CFM. The greater exact-output screen is 600 CFM. In the simplified selector, this appliance falls in the 60,000–79,999 BTU/h band, so the tool displays approximately 600–800 CFM. This planning interval does not yet identify which blower will deliver the needed airflow through the planned duct.

A suitable variable-speed system lets you use a lower setting for lighter cooking while retaining the capacity needed for the equipment and more demanding cooking conditions.

Start with the right appliance data.

Use an exact model and the applicable specification revision. Nominal width, fuel, burner output and ventilation requirements are separate pieces of information. A number labeled “total BTU” may include the oven; a burner chart may cover only the cooking surface. Mixing them creates a misleading calculation.

Verified appliance examples · surface output only
ApplianceWidth / fuelSurface outputHow to use it
Thermador PRG304WH30″ / gas66,000 BTU/hTwo 18,000 + two 15,000 BTU/h burners.
Thermador PRG366WH36″ / gas99,000 BTU/hThree 18,000 + three 15,000 BTU/h burners.
Wolf GR36636″ / gas84,200 BTU/hFive 15,000 + one 9,200 BTU/h burner.
Wolf CI30460T/S30″ / inductionNot a gas BTU inputInduction cooktop; electrical zones are not converted to gas BTU.
Thermador CEM305TB (existing appliance)30″ / electricNot a gas BTU inputLegacy electric model; actual glass width 31 inches.

Manufacturer specification sources are listed below. These examples explain how to read appliance data; they do not represent manufacturer approval of a CopperSmith hood pairing.

Wolf’s GR366 illustrates the distinction: its cooking-surface burners total 84,200 BTU/h, while Wolf’s total-appliance table lists 114,200 BTU including the oven bake burner. The applicable ventilation instructions determine which basis to use. Do not add the oven automatically or exclude it without checking the stated method.[4]

What size duct do I need for my range hood CFM?

For early planning, 600 CFM commonly points to an 8-inch round duct. Lambro’s recommended round-duct bands provide the comparison below. They are general guidance, not universal capacity limits or installation approvals.[12]

Round duct planning reference by airflow
AirflowRecommended round duct reference
Up to 400 CFM6 inches
Over 400 to 600 CFM8 inches
Over 600 to 900 CFM8–10 inches
Over 900 to 1,200 CFM10–12 inches
Over 1,200 CFM12 inches

Source: Lambro, Kitchen Ducts, recommended-size column. The calculator compares a bounded estimate at its upper endpoint. An open-ended estimate cannot establish a duct match. The listed reference is not a substitute for the selected equipment’s instructions.

Exact equipment can differ from general guidance. CopperSmith’s currently linked insert specification, revision December 1, 2021, lists an 8-inch duct for the 610-CFM integrated models and a 10-inch duct for its 1,260-CFM integrated models. These are documented product connections, not maximum airflow ratings for every duct of those sizes. Confirm the applicable model and current specification before ordering.[13]

Round versus rectangular ducts

A 3.25″ × 10″ rectangular duct has 32.5 square inches of area, compared with about 28.3 for a 6″ round duct. These shapes are not interchangeable on area alone. A larger round duct has more cross-sectional area. For the same airflow, air velocity is lower in the larger duct. But diameter alone does not establish a universal CFM limit. The route, length, fittings, termination, blower performance and manufacturer instructions also matter.

Round area (in²) = π × diameter² ÷ 4
Rectangular area (in²) = width × height
Air velocity (ft/min) = CFM × 144 ÷ area (in²)
Geometry comparison at an illustrative 600 CFM
Duct shape / sizeAreaVelocity
3.25″ × 10″ rectangular32.5 in²2,658 ft/min
6 inches round28.3 in²3,056 ft/min
8 inches50.3 in²1,719 ft/min
10 inches78.5 in²1,100 ft/min

Calculated from cross-sectional area and the airflow/velocity relationship. These are arithmetic comparisons, not acceptable-velocity limits, product ratings or duct-size approvals.

PNNL recommends smooth metal duct of the specified diameter and a direct route outdoors with few bends. Installed airflow can be below the factory rating because of the duct and termination. The useful next check is the selected blower’s performance at the system’s pressure—not simply buying a larger advertised number.[2]

Existing small duct? Keep the cooking estimate visible. Compare it with the chosen equipment and duct route, then determine whether the duct or system needs to change. Do not reduce the estimate just to make the existing diameter appear suitable.

How much wider should the hood be?

Matching the cooking surface is a general starting point. Where equipment instructions and available space allow, 3 inches of additional coverage on each side creates a hood 6 inches wider overall. A 42-inch hood over a 36-inch range illustrates that relationship.[5]

Architectural elevation: a 42-inch hood centered above a 36-inch range gives three inches of extra width on each side
A 42-inch hood adds 3 inches of coverage on each side of a 36-inch range. Vertical spacing is illustrative; follow the selected equipment’s mounting instructions.

Additional width is not universally optimal, a maximum, or a substitute for adequate depth. Check coverage over the front burners and the required mounting height. The decorative shell, the liner or insert, and the effective capture area are related dimensions; they are not interchangeable.

Resolve the proportions in the same drawing as the ventilation configuration. A larger outer shell does not automatically mean a larger filter opening, and the right insert cannot be inferred from a room rendering. Use actual product documents when confirming the insert’s dimensions, lights, controls and duct connection.

How do I size an island range hood?

The general width reference uses 150 CFM per foot for an island, versus 100 CFM per foot against a wall. For a 36-inch cooking surface, that gives 450 CFM versus 300 CFM before applicable gas-output or manufacturer requirements are considered. Open sides and cross-drafts make capture depth and front-burner coverage important.[1][2]

A higher ceiling does not authorize raising the hood above the equipment’s permitted mounting height. Resolve canopy height, chimney extension, structural support and the duct route while maintaining the specified distance above the cooking surface. Extra CFM cannot be assumed to compensate for excessive mounting height or inadequate capture.

Does kitchen size determine range hood CFM?

Kitchen floor area alone does not determine the airflow for a canopy hood. The hood captures emissions at the cooking surface, so appliance output, hood width, placement and the installed ventilation system are the relevant starting points. HVI’s general hood guidance uses range width and wall or island placement, with manufacturer guidance for professional-style equipment.[1]

Room-volume and whole-home ventilation calculations answer a different question. For example, 600 CFM in a 1,800-cubic-foot room equals 20 nominal air changes per hour: 600 × 60 ÷ 1,800. That arithmetic does not establish the capture performance or required airflow of the range hood. An open-plan kitchen still needs a hood proportioned and specified around the cooking equipment.

What about outdoor BBQ hoods?

Outdoor BBQ hoods require a separate assessment of the grill, hood coverage, mounting height, wind exposure and duct system. This indoor calculator does not assign a CFM estimate to BBQ installations. Review the exact grill and hood instructions, then explore CopperSmith outdoor range hoods.[9]

The other half of ventilation

Does your range hood need makeup air?

Exhaust air leaves the home. Makeup air provides a planned path for replacement air to enter.

A powerful exhaust system can create negative pressure and interfere with vented combustion appliances. Plan the exhaust and replacement-air systems together, especially in a tightly sealed home.[8]

What does the 400-CFM threshold mean?

The 2024 International Residential Code, Section M1503.6, calls for makeup air when an exhaust system can exceed 400 CFM and a fuel-burning appliance inside the home’s air barrier is neither direct-vent nor mechanically drafted. Where that provision applies, the replacement-air rate is approximately equal to the exhaust rate. Related sections address the supply location and damper operation.[10]

This is a model-code provision, not a nationwide yes/no rule. Your adopted code and amendments control. For example, Minnesota’s published mechanical rules include triggers above 300 CFM for certain existing-home installations, together with specific sizing methods and exceptions.[11]

Makeup-air planning questions
CheckWhy it matters
Maximum exhaust capacityReview the selected equipment’s capacity, not just the calculator’s lower estimate or the fan speed you expect to use.
Appliances throughout the homeAn electric or induction cooktop does not describe the venting arrangement of a furnace, water heater or fireplace.
Local requirementsConfirm the applicable code, supply-air amount, controls and location with the installer and building authority.

An estimate at or below 400 CFM does not establish an exemption. This calculator does not know your building’s pressure conditions, other appliances or jurisdiction, so it does not issue a compliance verdict or size a makeup-air system.

From an estimate to a complete system

The calculator is most useful early, when it helps a homeowner or designer ask better questions. Before ordering, resolve the actual cooking appliance, capture dimensions, mounting height, selected ventilation components and duct route together.

An integrated blower sits within the hood assembly. Inline and exterior blowers use different approved mounting arrangements, so identify the exact product before drawing its location or connections. CopperSmith describes remote configurations at approved exterior wall or roof locations. Every ducted arrangement carries exhaust outdoors; the duct must not terminate in an attic.[7]

Makeup air and pressure relationships also belong in the final review. Do not interpret an estimate below a familiar threshold as an automatic exemption. Applicable local requirements, combustion appliances and project conditions need to be considered with the installer. EPA identifies combustion backdrafting as a potential issue with high exhaust airflow.[8]

Once the technical arrangement is resolved, use the hood’s material, finish and proportion to complete the cooking wall. Explore CopperSmith range hoods and the corresponding ventilation options together, and confirm the specific combination before purchase.

Common range hood CFM questions

Does 600 CFM require an 8-inch duct?

An 8-inch round duct is the general planning reference at 600 CFM, and CopperSmith’s linked specification lists an 8-inch connection for its 610-CFM integrated models. This is not a universal rule for every 600-CFM blower: the exact equipment instructions, approved shape and complete duct route control.

How much CFM do electric and induction cooktops need?

The general width reference gives 250 CFM for a 30-inch wall location and 375 CFM for a 30-inch island location; at 36 inches it gives 300 and 450 CFM respectively. Follow the appliance instructions, especially for professional-style equipment. Electrical input is not converted to BTUs for the gas formula.

When would I need 900 or 1,200 CFM?

The stated gas-output screen gives 900 CFM at 90,000 BTU/h and 1,200 CFM at 120,000 BTU/h. These are arithmetic examples, not universal equipment requirements. A professional-style range, grill or griddle needs its own ventilation guidance. More advertised airflow does not replace adequate capture or a suitable duct system.

Is 600 CFM enough for my range hood?

It depends on the appliance and capture conditions. Under the gas-output screen, 60,000 BTU/h corresponds to 600 CFM. A 66,000-BTU/h cooking surface gives 660 CFM under the same arithmetic, so a 600-CFM label alone does not meet that screen. Confirm the applicable manufacturer guidance, installed airflow and makeup air.

Is 400 CFM enough for a 36-inch range?

It may fit some applications, but width alone cannot establish that. The general width screen for a 36-inch wall location is 300 CFM; a gas-output or model-specific requirement may be substantially higher. Check the appliance and the installed system rather than treating 400 CFM as a universal answer.

Does an induction cooktop need ventilation?

Cooking food can produce airborne particles even without gas burners. EPA recommends using the range hood while cooking to reduce exposure to cooking particles.[8] Follow the appliance guidance for airflow and capture; the gas BTU method does not apply to induction equipment.

Does cooking style affect ventilation?

Cooking intensity affects what the hood must capture. Look for usable lower speeds for light cooking and adequate capture and capacity for more demanding use. This calculator does not assign an arbitrary percentage to a cooking-style label; follow the appliance guidance for high-output or specialty equipment.

Can I use a 6-inch duct with a high-CFM blower?

A 6-inch round duct is below the general recommended reference once the estimate exceeds 400 CFM. Compare the selected blower’s instructions with the actual route. A manufacturer-approved system can differ from the general table; diameter alone does not confirm performance.

Why do I see a CFM range?

A BTU band describes several possible burner totals, so its result is approximate. For a 36-inch wall location, the 60,000–79,999 band gives roughly 600–800 CFM under the stated method. A cooking surface rated at 66,000 BTU/h falls in that same band. Its surface-output arithmetic is 660 CFM, but the calculator keeps the band-based display for consistency. These remain planning estimates; a band does not establish the appliance’s requirements.

Sources and methodology

Sources checked November 24, 2026. These references explain the planning methods and examples. Appliance instructions, the complete ventilation system and local requirements determine the final specification.

  1. Home Ventilating Institute: How Much Ventilation Do I Need? Kitchen range hood guidance and professional-style equipment qualification.
  2. Pacific Northwest National Laboratory: Kitchen Exhaust Fans. Outdoor discharge, duct construction and installed airflow considerations. Older code excerpts on the source page are not treated as universally current requirements here.
  3. Thermador Ventilation Planning Guide, document 8001303397_A. Stated BTU-based applications, specialty equipment and width guidance.
  4. Wolf GR366 specification sheet and GR Series total BTU reference. Surface and total-appliance figures are distinguished.
  5. CopperSmith: Selecting Range Hood Measurements. Width-matching starting point and additional side coverage.
  6. Thermador PRG366WH specifications. Surface burner outputs, September 2026 document.
  7. CopperSmith: Kitchen Ventilation. Component configurations and outdoor discharge.
  8. US EPA: Sources of Indoor Particulate Matter. Cooking particles, range hood use and combustion backdrafting considerations.
  9. CopperSmith: Outdoor Range Hoods and ventilation specification PDF, revision 12/01/2021, page 2. Outdoor planning factors and product-specific single/dual duct configurations; verify the applicable revision before ordering.
  10. 2024 International Residential Code, Sections M1503.6–M1503.6.2. Conditional makeup-air provisions, location and damper operation. Check the locally adopted edition and amendments.
  11. Minnesota Rules 1346.0501, Section 501.4. Example of jurisdiction-specific makeup-air requirements, including existing-home provisions and exceptions.
  12. Lambro: Kitchen Ducts. Recommended round-duct planning bands. Only the recommended-size comparison is used; the page’s older code discussion is not treated as current local law.
  13. CopperSmith Insert Fan Specifications, revision 12/01/2021, page 1. Product-specific 610-CFM / 8-inch and 1,260-CFM / 10-inch integrated-blower examples; verify the applicable current model before ordering.

Additional manufacturer documents are linked in the appliance table. Wolf matched-system references use its Design Guide, revised July 2025, page 147. The CEM305TB is an existing-appliance reference, not a current product recommendation.

Ryan M. Grambart